In Commom , The hydro turbines we use in projects as follows for your reference,

 

1???????????????????????????????????????????????????????????????addnew???????(?http://www.addnew.com.hk/hydropower%20turbines/index.html??
Kaplan Hydro Turbines (Propeller Turbines)        

      Runner diameters: 0.6-3m

      Suitable water head: H=3-30m
      Capacity of the generator unit: 160-20000kw
       The speed range of the turbine: 60-750rpm

       2?????????????????????????????????????????????2~30m?????????~?????
Tubular Hydro Turbines (Bulb Turbines)Runner diameters: 0.8-3.3m
    Suitable water head: H=2-30m
    Suitable flow: Q=1.62-53.6m3/s
    Capacity of the generator unit: 35-8700kw

3????????????????????????????????????????????????????????addnew??????????www.addnew.com.hk):Francis Hydro Turbines (Mixed Turbines)    Runner diameters: 0.35-2.5m
       Suitable water head: H=10-300m
      Capacity of the generator unit: 160-20000kw
      The speed range of the turbine: 150-1000rpm

    
       4????????????????????addnew??????????www.addnew.com.hk)
Pelton Hydro Turbines (Impulse Turbines)

Suitable water head: H=100-1000m
    Suitable flow: Q=0.13-5.81m3/s
    Capacity of the generator unit: 200-20000kw
    The speed range of the turbine: 250-1000rpm

 

5?????????????????????????
Inclined jet Hydro Turbines (Turgo Turbines) Suitable water head: H=40-300m
    Suitable flow: Q=0.35-1.166m3/s
    Capacity of the generator unit: 100-1250kw
    The speed range of the turbine: 600-1000rpm

 

?source from addnew?

1039 Views Comments 0 Comments Comments Add Comment Author BioAuthor Bio
ReportReport This Post as Foul/Inappropriate
 
Toolbox

Blog Editor
Search
Calendar
Recent EntriesRecent Entries
Recent CommentsRecent Comments
RSS
Energy Central
Power Network


Sponsored Content

Copyright © 1996-2012 by CyberTech, Inc. All rights reserved.
Energy Central ® is a registered trademark of CyberTech, Incorporated.
CyberTech does not warrant that the information or services of Energy Central will meet any specific requirements; nor will it be error free or uninterrupted; nor shall CyberTech be liable for any indirect, incidental or consequential damages (including lost data, information or profits) sustained or incurred in connection with the use of, operation of, or inability to use Energy Central.
2821 S. Parker Rd. Ste 1105 Aurora, CO 80014
Contact: Phone - 303-782-5510 Fax - 303-782-5331 or service@energycentral.com.